Sysmex ufi flow cytometer capability to discriminate. In this study, 358 urine samples were analyzed with the sysmex uf i in parallel with manual microscopy, gram stain and bacterial culture, the latter considered the gold standard. Advanced flow cytometrytechnology with hydrodynamic focusing specific fluorescent dyesfor bacteria and sediment 3 highdefinition, reproducible measurement signals. Rbc, wbc, epithelial cells, cast, and bacteria and flags the presence of the following. The sysmex xs i showed good correlation with xe2100, cd4000 and the manual reference leucocyte differential. Ufi is a fully automated, urinary screening system which bases its objective analysis on. A new generation automated urine particle analyzer sysmex. Seite 4 ansicht qc files qcdateien 72 ansicht qc chart. Background candiduria is common in hospitalized patients.
Its management is limited because of inadequate understanding. The uf i has good agreement with the reference methos for wbc, rbc and ec. Using fluorescence flow cytometry, the ufi offers two separate channels. The uf i system sysmex, kobe, japan, based on flow cytometry, provides small red blood cell rbc values uf i uf %srbcs. Overall flagging sensitivity and specificity were 91% and 48%, respectively. Substantial table i shows substantial equivalence of the uf i to the uf 100. In fact, we proved the performance of the sysmex ufi bacteria count in reducing urine cultures for uti is superior to uf100s. Uf500i is sysmex latest urine fluorescence flow cytometer. To enhance security, these are located on a separate server and therefore on a separate website. The uf i analyzes the following parameters in urine samples. They reflect our drive for excellence and our profound love of knowledge. Its fluorescence flow cytometry technology delivers extremely high quality all round.
For blood cell counts we use fluorescence flow cytometry, e. A new concept and a comprehensive evaluation of sysmex uf. The stored information can be resent to our servers the next time you visit the website. A cookie is a simple small file sent with the pages of this website and stored by your browser on the hard disk of your computer. Sysmex uf500 medical laboratory equipment sysmedlabs. With its stage scanning technology, you confirm abnormal results from previous chemical and sediment analysis in a fully automated device. Models xsi closed tube sampling xsi with auto sampler closed tube xsi system includes xsi analyzer 12. Performance of the sysmex ufi urine analyser in the. Using a unique and advanced diode laser bench, sysmex fluorescent flow cytometry provides the sensitivity needed for measuring and differentiating cell types in whole blood and body fluid. Sysmex sterilizer to view the sysmex sterilizer safety data sheet english, click here. We evaluated the clinical application of uf%srbcs for. Pdf the standardization of the report for urine cell countinga. Sysmex sustainability data book in fiscal 2019, we changed the name of the sysmex sustainability report to the sysmex sustainability data book. Detects potential urinary tract infections within a minute, not hours.
Manufacturer specifications uf 100i, sysmex please note. Pdf evaluation of the sysmex ufi urine flow cytometer in. Ez azt jelenti, hogy a lehetseges hugyuti fertozeseket orak helyett mindossze egy perc alatt felismeri, akar orankenti 100 mintas sebesseggel. The ufi uses fluorescent dyes to stain the formed elements in urine. We evaluated the clinical application of uf %srbcs for. The analysis of white blood cells wbc in cerebrospinal fluid csf is a key diagnostic element for the different diagnosis of a kaleidoscope of diseases, thus including inflammatory conditions and infectious or noninfectious disorders involving the cns. The xs i and the xs800i, suitable for minimal sample throughput, are part of the xclass, whose outstanding feature is the unique system of fluorescence flow cytometry for white blood cell wbc differentiation. In fact, we proved the performance of the sysmex uf i bacteria count in reducing urine cultures for uti is superior to uf 100s.
The sysmex uf i is a urine flow cytometer that uses two separate channels for counting blood cells and bacteria. We would like to present the experience gained with xsseries with a focus on paediatric blood analyses. Sysmex ufi is an automated urine particle analyzer for in vitro diagnostic use in screening patient populations found in clinical laboratories. Pdf automation and standardization of sediment analysis of urine samples by flow cytometry might serve as an.
Sysmex ufi analyzer urinalysis automation laboratory stack. The xsi may be compact, but it uses the same globallyrenown detection technologies as sysmexs larger analysers. The sysmex ufi is a urine flow cytometer that uses two separate channels for counting blood cells and bacteria. Ufi highquality urinalysis at the touch of a button our new ufseries of urinalysis devices is unique. And despite being the smallest, its quality is undiminished.
Uf50004000 sysmex india hematology instrumentation. Siemens connects the ufi with our clinitek novus urine. Uc uc3500 ud10 uf50004000 ux2000 xe5000 xn check xn check bf xn xn pure xn1500 xn2000 xn3000 xn31 xn3100 xn350 xn450 xn550 xnl pure xnv series. Results obtained using passingbablok regression analysis, that allows estimation of analytical methods agreement. The principle of fluorescence flow cytometry is used in different analysers for haematology and urinalysis.
Sysmex today offers the fluorescence flow cytometers ufi and uf500i with the advantageous semiconductor laser technology for the analysis of urine. Previous epidemiological studies based on culture assay have been limited to small study populations. Hematology analyzer sysmex xn clia moderate complexity sysmex america xn100bpr. In conclusion, the sysmex xsi demonstrated good analytical performance, is able to generate a complete blood count with fivepart differential on low. Performance evaluation of the sysmex xsi automated. Manufacturer specifications uf100i, sysmex please note.
Ufi ufi for the automated detection and enumeration of bacteria and particles in urine urinary screening smart technology. Sysmex ufi flow cytometer capability to discriminate gram negatives and gram positives in urine background. Sysmex uf i is an automated urine particle analyzer for in vitro diagnostic use in screening patient populations found in clinical laboratories. Volume 8, number 3 july 2014 test updates billings clinic. Fully automated, rapid sample processing enhances laboratory workflow. Particles can be classified into eight different classes based on the size of particles. Ufi, a flow cytometer for the evaluation of the particulate. It can be used as a standalone analyzer, or as part of the modular unseries for a truly walkaway, seamless urinalysis workplace solution from sample loading to the final digital image. The ufi system sysmex, kobe, japan, based on flow cytometry, provides small red blood cell rbc values ufi uf%srbcs.
Therefore, data collected by automated systems from a large target population are necessary for more comprehensive understanding. The ufi analyzes the following parameters in urine samples. Manual cell counts were compared with cell counts of sysmex uf i. That workstation, foohey says, has been available in the united states since the beginning of the year and is also for sale in canada and japan. A vizeletelemzo eszkozeink uf sorozata egyedulallo.
Fortyfour csf samples were used for method comparison studies between sysmex xn9000 body fluid mode and conventional optical microscopy. The use of fluorescent flow cytometry for urinalysis is a substantial innovation of the sysmex uf series. Sysmexs proven technology offers laboratories a break. Sysmex house garamonde drive wymbush milton keynes mk8 8df phone 448709029210 fax 448709029211 uk sysmex singapore pte ltd. Uf 500i is sysmex latest urine fluorescence flow cytometer. A brief introduction the sysmex xe5000 automated hematology system utilizes the power of fluorescent flow cytometry and hydrodynamic focusing technologies. Sysmex ca500 blood coadulation analyzer user manual 2. This study was planned to evaluate the analytical performance of the novel and fully automated sysmex xn9000 analyzer for rapid analysis of cerebrospinal fluid csf samples.
Thank you for your interest in our instructions for use ifu, certificates, package inserts or standard operating procedures. The screening model was built on the observed bacterial and leukocyte counts. To view the sysmex sterilizer safety data sheet french, click here. This publication is intended to complement integrated reporting content, and contains detailed information related to sysmexs environmental, social and governance esg efforts. None of the equipment posted for sale on is owned by medwow, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page. Ufi a fluoreszcencia aramlasi citometriaval az uf i ket kulonallo csatornat kinal. Sysmex uf i medical laboratory equipment sysmedlabs.
Evaluation of the sysmex ufi urine flow cytometer in. To view the sysmex sterilizer safety data sheet spanish, click here. The sysmex uf i using a dedicated bacterial channel and additional sidescatter information aids to revise a new exploration of urinalysis flow cytometry. In the ufi and uf500i analysers, the urine sample is split in two separate aliquots and mixed with special reagents at a fixed dilution ratio. The sysmex ufi using a dedicated bacterial channel and additional sidescatter information aids to revise a new exploration of urinalysis flow cytometry. Uf ii control leveyjennings and xbar m quality control programs accessories graphic printer dimensions weight main unit. Sysmex sustainability data book sustainability sysmex. Sysmex uf i, automated urine particle analyzer 11 510k fda submission. Rapid identification of bacterial pathogens in urine is essential to prescribe an adequate empirical antibiotic therapy to treat urinary tract infections utis. Uf cal to view th uf cal safety data sheet spanish, click here. Conclusion the uf i demonstrates substantial equivalence to the predicate device. News sysmex korea, hbsag, hiv test reagent received mfdss approval of ivd class 4 read more. The sysmex xsi showed good correlation with xe2100, cd4000 and the manual reference leucocyte differential. And thanks to its absolute counting principle, you dont need to calibrate the particle counts yourself, which will save you a significant amount of time and effort.
This novel technology enables the uf series to differentiate between cell populations without technologist intervention or visual identification of formed elements. The infections of the central nervous system cns are conventionally classified as meningitis or encephalitis. Ufi is a fully automated, urinary screening system which bases its objective. Evaluation of body fluid mode of sysmex xn9000 for white. The uf i enhances work flow efficiency in the clinicl laboratory by offering true walkaway capability, freeing the technologist from many of the laborintensive steps of manual urine microscopy. Red blood cells, platelets, haemoglobin and haematocrit. Accessories graphic printer dimensions weight main unit. Within the unseries, the ud10 closes the total urinalysis workflow by capturing the particle images in urine samples. Fully automated, rapid sample processing enhances laboratory workflow, improves turnaround times and frees skilled technologists to devote their time to other laboratory priorities.
Based on diode laser technology using polymethine dyes specifically staining nucleic acids, sensitive particle analysis with particularly sensitive bacteria detection at clinically relevant levels could be achieved. Xsi low aspiration volume, compact closed system, excellent analysis. A fluoreszcencia aramlasi citometriaval az uf i ket kulonallo csatornat kinal. The ufi bases its objective analysis on both physical and chemical particle properties. Sysmex uf i flow cytometer capability to discriminate gram negatives and gram positives in urine background. Detects all three uti indicators in one go, at up to 100 samplesh. Sysmex to introduce new globally consistent jobbased hr management system with the aim of realizing sustainable growth mar. Pdf evaluation of the sysmex ufi urine flow cytometer. Uf i, a flow cytometer for the evaluation of the particulate. The sample aliquots will thus be prepared for the subsequent analysis processes.
The use of fluorescent flow cytometry for urinalysis is a substantial innovation of the sysmex ufseries. All in one computermonitor bar code reader laser printer auto sampler optional. Uf i is a fully automated, urinary screening system which bases its objective analysis on both physical and chemical particle properties. Sysmexs proven ufi technology offers laboratories a breakthrough in automation, standardization and efficiency. The uf i uses fluorescent dyes to stain the formed elements in urine.
Analyzer specifications uf500i provides those urine analysis results you need fast while freeing you up for other important tasks. Using fluorescence flow cytometry, the uf i offers two separate channels. This means you can now detect possible urinary tract infections in about one minute instead of hours, and at a rate of up to 100 sampleshour. In conclusion, the sysmex xs i demonstrated good analytical performance, is able to generate a complete blood count with fivepart differential on low. The ufi offers accurate and precise particle counts on uncentrifuged urine samples.
In this study, 358 urine samples were analyzed with the sysmex ufi in parallel with manual microscopy, gram stain and bacterial culture, the latter considered the gold standard. The xs500i may be compact, but it uses the same globallyrenown detection technologies as sysmexs larger analysers. Ufi highquality urinalysis at the touch of a button. Xsi low aspiration volume, compact closed system, excellent analysis the xsseries is the latest addition to sysmexs xclass haematology analysers. Request pdf performance of the sysmex ufi urine analyser in the rapid diagnosis of urinary tract infections in hospitalized patients background.
Xs500i enter the world of sysmexs 5part differential analysis and despite being the smallest, its quality is undiminished. Flow cytometry analysis was performed using the ufi instrument sysmex, toa medical electronics, kobe, japan, supported by the sysmex software version of 0015. This novel technology enables the ufseries to differentiate between cell populations without technologist intervention or visual identification of formed elements. The ufi is a flow cytometer which automates the urine microscopic, thereby providing efficiencies in testing by reducing handsontime, minimizing manual urine microscopic analyses and improving overall tat. The xsseries is the latest addition to sysmex s xclass haematology analysers. The uf5000, based on sysmexs globally renowned fluorescence flow cytometry ffc, represents the latest in urinalysis technology. Find any required sysmex urine analyzer, automated equipment or device. Pdf with my 920 every so often i would get a message from mysysmex son that was almost a week poch old. Quality control 24 files with 300 data points each sysmex control material. The ufi enhances work flow efficiency in the clinicl laboratory by offering true walkaway capability, freeing the technologist from many of the laborintensive steps of manual urine microscopy.
1355 783 999 428 313 153 822 768 1080 891 965 1037 382 88 1256 1175 159 293 450 184 72 464 506 800 181 96 851 920 566 1285 1497